Void
Former
Also
known as Expanded
Paper Honeycomb often referred to as EPH.
EPH panels can be used in reactive soil areas under slabs and beams
in a pier or beam and slab type structure. They provide safe and
economical temporary support which eventually deteriorates leaving
a void beneath the concrete.
EPH panels are designed to lose their strength in moist conditions
thus care must be taken to lay out areas where the concrete will
be poured immediately once the EPH is in position. Walkways should
be provided for workmen in heavy traffic areas. Point loading must
be avoided at all times.
Each EPH panel is supplied wrapped in plastic to help with
weather protection but is not weather proof and must be stored in
a dry place. Tarpaulin covers are recommended and need
to be laid to allow adequate ventilation. Minimum ground clearance
during storage is 100mm and supports should be run along the length
of the panels.
Panels are a standard size of 2500x800 with the thicknesses
varying depending on specification requirements.
Available thicknesses:
50mm - available ex-stock
75mm
100mm - available ex-stock
150mm
200mm
Strength
Results - kg/m2
50mm depth - 799 kg/m2
75mm depth - 1027 kg/m2
100mm depth - 1050 kg/m2
Sample size used for above results 300x300mm face.
|